Home|Journals|Articles by Year|Audio Abstracts
 

Original Article

J App Pharm Sci. 2021; 11(12): 121-134


Stability-indicating RP-HPLC method development and validation for simultaneous estimation of bisoprolol fumarate and amlodipine besylate in bulk and in tablet dosage form

Rameshwar Bhausaheb Gholve, Sanjay Sudhakar Pekamwar, Tukaram Mohanrao Kalyankar.




Abstract
Cited by 0 Articles

A novel chromatographic method has been developed with a stability-indicating feature for simultaneous estimation of bisoprolol fumarate (BSL) and amlodipine besylate (AMD) in bulk and in tablet dosage form with minimized drug extraction steps. The chromatographic analysis was executed by the isocratic elution mode using Oyster ODS3 (150 × 4.6 mm, 5 μm) column (Merck & Co.) as the stationary phase at ambient temperature (about 25°C) with 1.0 ml/minute flow rate and 20 mM phosphate buffer with pH 2.5 (adjusted by 5% orthophosphoric acid):methanol:acetonitrile (42:29:29, v/v/v) as eluents at a wavelength of 230 nm. The retention time was found to be 2.543 and 4.883 minutes for bisoprolol and amlodipine, respectively. The method was found to be linear in the concentration range of 60.08– 140.19 μg/ml for BSL and 59.73–139.37 μg/ml for amlodipine with squared correlation coefficient (R2) of 0.999 in both cases. Individual drug substances and their combination drug product were exposed to conditions like acid, alkali, oxidative, thermal, photolytic, and humidity degradation; the degradation peaks were well separated from active analyte peaks. The acid-, alkali-, thermal-, and photolytic-induced stress studies signified the formation of a variety of degradants. Hence, it is recommended that BSL and AMD drug substances, as well as drug products, should be stored in tightly closed container protected from light and heat. The method was validated for specificity, linearity, quantitation limit, detection limit, accuracy, precision, robustness, and solution stability as per International Conference on Hormonization (ICH) guidelines and effectively used for regular analysis.

Key words: RP-HPLC, Bisoprolol, Amlodipine, Forced Degradation, Solution Stability, Validation






Full-text options


Share this Article


Online Article Submission
• ejmanager.com




ejPort - eJManager.com
Refer & Earn
JournalList
About BiblioMed
License Information
Terms & Conditions
Privacy Policy
Contact Us

The articles in Bibliomed are open access articles licensed under Creative Commons Attribution 4.0 International License (CC BY), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.