Predictive Values of Optical Coherence Tomography (OCT) Parameters in Assessment of Glaucoma progression

Sanja Sefic Kasumovic, Aida Kasumovic, Suzana Pavljasevic, Emir Cabric, Milka Mavija, Irena Sesar, Sabina Dacic-Lepara, Mirko Jankov.




Abstract

Goal: the purpose of the current study was to estimate the predictive values of optical coherence tomography parameters in early, developed perimetric and terminal glaucoma. Methods: 180 eyes of 120 consecutive patients were evaluated in this retrospective cross sectional pilot study. Copernicus Spectral –domain optical coherence tomography with resolution of 3 mm obtained throught the optic nerve head were included. All examined eyes were divided to four groups (healthy,early, developed perimetric glaucoma and terminal glaucoma). The values of the thicknes of the retinal nerve fibre layer, the size of the disk, the volume of the cup, the E/D parameter and the size of the RIM were compared in four study groups. Results:The sensitivity of RNFL was 90,0%, specificity 82,0 %, positive predictability 83,3 % and negative predictability was 89,1 %. The total accuracy was 86,0 % and area under curve (AUC) was 0,878 for RNFL indeks compering early to developed glaucoma. The sensitivity for CUP was 78%, the specificity was 80,8 %, the positive predictability 81,2% and the negative predictability was 77,5 %. The total accuracy was 79,3 % and area under curve (AUC) was 0,86 compering early to developed glaucoma. The sensitivity for E/D was 82,0%, the specificity was 82,9 % the positive predictability 83,7 % and the negative predictability was 81,3 %. The total accuracy was 82,5 % and area under curve (AUC) for E/D was 0,89 compering eearly to developed glaucoma.The sensitivity for RIM was 78,0%, the specificity was 76,6 %, the positive predictability was 84,7 and the negative predictability was 67,7 %. The total accuracy was 77,5 % and area under curve (AUC) for the RIM compering the developed to terminal glaucoma was 0,792. The sensitivity of RNFL was 88,0 %, the specificity was 66,7 %, the positive predictability was 81,5% and the negative predictability was 76,9%. The total accuracy was 80,0% and the area under curve (AUC) for RNFL compering developed to terminal glaucoma was 0,815. The incrreasing 0,1 unit RNFL decreases the risk of developing glaucoma from early to another developed stage of glaucoma for 6,95%. The increasing of E/D for only one unit increases the risk to develop another stage of glaucoma for 18,75 times. The increasing of RNFL for only one unit decreases the risk of performing developed glaucoma from initial stage for 7,8%. The increasing for only one unit of CUP increases the risk to develop terminal glaucoma for 8,47 times and increasing for 0,1 unit of the value of RIM decreases the risk developing terminal glaucoma for 9,27%. The increasing for 0,01 unit of the E/D index increases the risk for terminal glaucoma for 23,23 times. The increasing for one unit of RNFL decreasing the risk developing terminal glaucoma for 5,7%.

Key words: glaucoma, progression, optical coherence tomography, optic disc morphology.






Full-text options


Share this Article


Online Article Submission
• ejmanager.com




ejPort - eJManager.com
Refer & Earn
JournalList
About BiblioMed
License Information
Terms & Conditions
Privacy Policy
Contact Us

The articles in Bibliomed are open access articles licensed under Creative Commons Attribution 4.0 International License (CC BY), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.