EEO. 2021; 20(3): 3383-3390 Effect Of Unglazed Solar Flat Plate Collector On Thermal Efficiency And Outlet Temperature
Abhishek Rohatagi, Digvijay Singh, Paras Chauhan, Akashdeep Negi, Rajesh P. Verma, R. Dobriyal, D.B. Singh, Ms Priya Arundhati. Abstract | | | | The Present research article deals with the experimental investigation of an unglazed flat plate collector for the climatic condition of Dehradun, Uttarakhand, India. In the present study water is used as the working fluid, and the mass flow rate and temperature of inlet water was kept fixed at 0.0051kg/sec and 32˚C from the preliminary investigation. The experiment was carried out for two consecutive days and the outlet temperature of the unglazed flat plate collector was found to be 36˚C and 37˚C with the instantaneous efficiency of 11.11% and 13.79% for with the maximum solar intensity of 1140W/m2 and 1145W/m2 respectively for the day 1 and 2. The study shows without glazing material the outlet temperature was directly proportional to the solar intensity also the maximum heat gain during experimentation was found for day 2.
Key words: Unglazed Flat Plate Collector, Instantaneous Efficiency, Heat Gain, Mass Flow Rate.
|
|
|
|